Mechanical Thermostats

RAA31

Mechanical Room Thermostats – basic

Mechanical room thermostats for heating or cooling applications.

RAA11room thermostat, heating only or cooling only, 8..30°C, 230Vac, 6A, tamper proofDownload Datasheet
RAA21room thermostat, heating only or cooling only, 8..30°C, 230Vac, 6ADownload Datasheet
RAA31room thermostat, heating only or cooling only, 8..30°C, 230Vac, 6A, on/off switchDownload Datasheet
ARG70thermostat accessory, mounting plate for 4 x 4 conduit boxes
ARG70.1thermostat accessory, mounting plate for 2 x 4 conduit boxes

RAMTR2000M

Mechanical Thermostats – clamp on

Electromechanical temperature limitation with single pole changeover micro switch. Control medium: water, oil

RAM-TR.2000Mthermostat, control type, pipe mounting, 17..90°C, external setpoint adjusterDownload Datasheet
RAM-TW.2000Mthermostat, control type, pipe mounting, 17..90°C, internal setpoint adjusterDownload Datasheet

RAMTW5000

Mechanical Thermostats – outside air temperature

Mechanical thermostats for plant room or outdoor applications.

RAK-TW.5000HSthermostat, immersion strap on or wall mount, 1600mm capillary, IP65, 5 to 65°CDownload Datasheet
TC3-543230imit thermostat, IP42, 0..50°C

RAKTR1000

Mechanical Thermostats – capillary

Thermostats with adjustable temperature, deviation capillary with bulb.

KIT-90panel mount thermostat, 0 to 90°C, 1.5m capillary, 16A, c/w knob and bezel
RAK-TR.1000B-Hthermostat, control type, 700mm capillary, 15..95°C, includes pocketDownload Datasheet
RAK-TW.5010S-Hthermostat, frost protection, 1600mm capillary, -10..50°CDownload Datasheet

Mechanical Thermostats – limit

RAKST1300

Siemens limit thermostats for use in heat generation plants and for general use in heating, ventilation and air conditioning plants.

  • for general use in heating, ventilation and air conditioning plants
  • single pole changeover microswitch
  • pipe, pocket or wall mount options available
  • visible switch off temperature
  • typically ex stock subject to prior sales
RAK-ST.1300P-Mthermostat, safety limit, 700mm capillary, manual reset, 120..130°C, includes pocketDownload Datasheet
RAK-ST.1310P-Mthermostat, safety limit, 700mm capillary, manual reset, 90..110°C, includes pocketDownload Datasheet
RAK-ST.1430S-Mthermostat, safety limit, 1600mm capillary, manual reset, 80..100°CDownload Datasheet
RAK-TB.1400S-Mthermostat, limit, 700mm capillary, manual reset, 45..60°CDownload Datasheet
RAK-TB.1410B-Mthermostat, limit, 700mm capillary, manual reset, 50..70°C, includes pocketDownload Datasheet
RAK-TB.1420S-Mthermostat, limit, 700mm capillary, manual reset, 65..80°CDownload Datasheet
RAK-TR.1000B-Hthermostat, control type, 700mm capillary, 15..95°C, includes pocketDownload Datasheet
RAK-TW.5010S-Hthermostat, frost protection, 1600mm capillary, -10..50°CDownload Datasheet
ALT-SB100protection pocket, single, brass, 100mm, ½” BSP (not incl.)
ALT-AB200thermostat accessory, protection pocket, for TKM2D (not incl.)
RAZ-ST.030FP-Jthermostat, combined control & safety limit, 15..95°C, switch off at 110°C, includes pocketDownload Datasheet
RAZ-ST.1500P-Jthermostat, combined control & safety limit, 15..95°C, switch off at 110..130°C, includes pocketDownload Datasheet
RAZ-ST.1510P-Jthermostat, combined control & safety limit, 15..95°C, switch off at 90..100°C, includes pocketDownload Datasheet
ALT-DB100protection pocket, double, brass, 100mm (not incl.)